Parameter
Value Description Default Exam.1 Exam.2
32 hhhhhh
External access code in
DAY + NIGHT mode
- 1212 1324
33 hhhhhh
External access code in
DAY mode
- 2211 2211
34 hhhhhh
External access code in
NIGHT mode
- 1122 1122
hhhhhh – password for relay closing from buttons [2 to 6 digits]
The 3 passwords are controlled by Day/Night; the combination is entered using
the unit buttons. It is influenced by the setting of Relay mode and Day/Night
switchover. When set to 2-group mode the unit is permanently in DAY mode.
Follow these rules when choosing password combination:
Select passwords carefully, to prevent their discovery from wear on
buttons caused by frequent use.
Select the first password button from infrequently-used buttons for
direct dialling (-extends choice time)(-not valid for keyboard).
Note: The switchover to Day/Night mode remains set in unit even after line
disconnection.
Parameter
Value Description Default Exam.1 Exam.2
35 aa
Internal access code
55 55 55
aa – command from phone to relay closing [2 digits]
It is recommended to set the same command for Internal Access Code and
End Call (parameter 43) aa=bb.
Parameter
Value Description Default Exam.1
Exam.2
36 ss
Relay closing time [sec]
05 02 05
ss – duration of relay closing [2 digits 01-99]
Parameter
Value Description Default Exam.1
Exam.2
37 pp
Time between 2 impulses
[sec]
05 05 05
pp – duration of delay between 2 impulses of relay [2 digits 01-99]